C.5.32 IP Port Setup Menus
This menu provides the setup parameters for the each IP output port.
Table C.40: IP PORT 1 and 2 Setup Menus
Menu title:
SET:IP PORT 1,
SET:IP PORT 2
Description Section
Port Enable: This item enables the relevant IP port.
On – Switches the port on.
Off - Switches the port off. No packets will be
output regardless of other IP output settings.
Default = On.
----
Link:
Auto – Auto negotiates the link it is connected
to.
10 MB Full - Force 10 Mbps full duplex
operation
100 MB Full – Force 100 Mbps full duplex
operation
Default = Auto.
Note: In Auto mode, only 10 Mbps and
100 Mbps are supported.
----
PING:
This item is used to configure how the unit will
respond to PINGs.
Enable – The IP port will respond to any
PINGs received.
Disable - The IP port will not respond to any
PINGs received.
Default = Enable.
----
ARP:
This item is used to configure how the unit will
respond to ARPs.
Enable – The IP port will respond to any ARPs
received.
Disable – The IP port will not respond to any
ARPs received.
Default = Enable.
----