12. REMOTE ACCESS
This section describes installing and configuring an optional Hayes modem which will allow remote access to the
Network Manager.
12.1 OVERVIEW
An optional modem may be connected to the Network Manager in one of three ways:
1. Modem connected directly to the HP Workstation.
2. Modem connected to the HP
Server.
3. Modem connected into a Terminal Server on the EDACS LAN.
12.1.1 Modem-HP Workstation Serial Port Connection
ModemModem
PC
COM1
NM
Work
station
Serial
Port
Phone
Lines
Figure 11 - Modem to HP Workstation Installation
This is the recommended EDACS Network Configuration for remote access. Its primary advantage is that remote access
is still possible when the EDACS LAN is not operational. The maximum baud rate is limited to 19,200 bits/second by the
serial port on the HP workstation.
NOTE
Neither of the modems in this configuration is the standard server HP Support Link Modem. The HP Support Link
Modem is limited to a baud rate of 2400 bits/second.