ON-SITE CONFIGURATION LBI-39171
61
4. Enter the comm command to define which Network Manager Station may read or write to this platform.
For example: pSH+>
comm -a -i
IP Address of NM
-c edacs -v write
5. Execute the stat command to verify that the CAM link is up. (Check the last line of information on the screen
for the CAM status of either “on line” or “off line.”)
For example: pSH+>
stat -i
8.4 EDG SETUP
Ensure that the EDG contains the following settings for Network Manager connectivity.
1. Log into the EDG under the root account.
Login: root
Password:
2. Change directories by entering
>
cd
cnfg
<ENTER>
3. Edit the SYSTEM.TXT file and add the following in IP section
[
IP
]
of the file: (
NOTE:
There is no local
editor.)
CAP_Ext_Address
IP Address
4. Reboot EDG.
NOTE:
The subnet mask depends on the class of the IP address and is not changeable. Refer to LBI-38964,
EDACS Data Gateway Configuration Reference manual for additional details.
8.5 SYSTEM MANAGER SETUP
NOTE
NOTE:
The System Manager’s Network Manager interface requires a System Manager software version Group 6
(or later) and MultiNet software. Before proceeding with this procedure, locate the licenses for these software
packages. The information found on these licenses will be used during setup.
8.5.1 Software Installation And Configuration
NOTE
A system disk image backup must be performed prior to S/W installation.
1. Perform a system disk backup prior to starting. (If necessary, refer to LBI-38703)
2. Install the EDACS System Manager group 6 software as described in the Software Release Notes.
3. Install and configure the MultiNet V3.5 software as follows:
NOTE