Ericsson TT1222 Guide de l'utilisateur Page 18

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 198
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 17
Introduction
1.2.4 Conditional Access
The transport stream received by the IRD may be encrypted. The CA system is
used to decrypt the required components of the transport stream so that they can be
decoded.
The following conditional access systems are available:
DVB Common Interface
EBU Basic Interoperable Scrambling System BISS Mode 1 and Mode E (as
specified in EBU Tech 3292 May 2002)
Director (Option). Over-air remote control is available if the TT1222 is used as
part of a Director system (over-air software downloading, re-start, tuning and
retuning etc.)
The different CA options may be used, for example: Director and BISS, however,
streams with mixed CA are not supported.
1.3 TT1222 Control Modes
1.3.1 Introduction
The TT1222 is designed for unattended operation. Once set up, it requires no
further attention except to ensure that the fan is working. There are four control
methods associated with the Receiver, front panel, remote control (RS-232),
nCompass/web browser (Ethernet) and Director.
In Local control mode, the TT1222 may be controlled by the front panel, web
browser or nCompass Control.
In Remote control mode, the TT1222 may be controlled by Ericsson RS232
proprietary control solution.
In Director mode, the TT1222 may be controlled by DirectorV5 NCP over-air control
commands.
Note: Local Control is the factory default.
1.3.2 Unit Control
1.3.2.1 Front Panel
The receiver is controlled using the front panel menus.
The unit must be set to ‘local’ control to use this mode.
EN/LZT 790 0002/2 R1A
1-8
Vue de la page 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 197 198

Commentaires sur ces manuels

Pas de commentaire