Front Panel LCD Menus
Menu title: SET:SELECT
ALARMS
Description Section
IP OUT > * Enters the IP OUT alarms submenu.
Note: * This item will only appear if a Dual IP
output module is fitted.
Annex D
For further information on what the different alarms mean, refer to Annex D, Alarm
Categories and Conditions.
C.5.16 CVBS Output Menu
This menu allows the Colour Video Black Sync output alarm conditions to be set.
Table C.24: CVBS Output Menu
Menu title: SET:CVBS
OUTPUT
Description Section
Alarm State:
Selects the format of the CVBS output if an
alarm is raised.
Sync - The CVBS output will not be affected
by an alarm condition and will continue to
output a valid video signal (with sync pulse).
NoSync - The CVBS output will have no sync
pulses.
Default = Sync.
----
Delay State:
Selects the number of seconds an alarm
should be present, before the CVBS output
goes to NoSync.
Note: This item only applies if the Alarm state
is set to NoSync.
Range = 0-999.
----
Hold State:
Selects the number of seconds an alarm
should be absent, before the CVBS output
alarm is cleared.
Note: This item only applies if the Alarm state
is set to NoSync.
Range = 0-99.
----
EN/LZT 790 0002/2 R1A
C-26