Vue de la page 4
19A705178
REV NO. TITLE
CONT ON SHEET
6
SH NO.
5
ROCKWELL MODEM TEST
SPECIFICATION/PURCHASE PART DRAWING
CONT ON SHEET SH NO. FIRST MADE FOR
F. C. F. O.
MADE BY
K P Dotson 11-19-86
APPROVALS
DCB
M. R. P. D.
DIV OR DEPT.
19A705178
ISSUED
Nov. 19, 1986
11-18-86
LYNCHBURG
LOCATION
CONT ON SHEET
6
SH NO.
5
REVISIONS
L30
PRINTS TO
3.0 SPECIFICATIONS
3.1 POWER SUPPLIES
13.8 volts nominal GETC power supply.
Refer to the GETC test specification (19A705179).
Modem Input Power +5 Volts +/-5% < 700 Ma
+12 Volts +/-5% < 20 Ma
-12 Volts +1-5% < 80 Ma
3.2 DATA RATE
Data Rate 9600 +1 -1 Bit/Second
Input Level Range - 43 dBm to 0 dBm
Output Level 0 dBm
Train Time 30 msec
3.3 APPLICABLE DRAWINGS
DRAWING NO. DRAWING NAME
19D901868 GETC SHELF
19D901855 GETC LOGIC BOARD ASSEMBLY
19D901852 GETC LOGIC BOARD SCHEMATIC DIAGRAM
Vue de la page 4