Maintenance
4/1553-HSC 901 101/2 Uen B 2009-02-27
39
7 Maintenance
The only parts that should be replaced from time to time in the EDN312,
ESN108 and EXN104 are the fans. There is no maintenance work for the
EPN102.
Each node has two fans. The speed of the fans is regulated according to
the temperature. An alarm is issued if a fan stops.
The node will check both fans every 24 hour to validate the quality of the
fan, based on revolutions per minute (rpm) at full speed. An alarm is issued
if a fan fails to reach a specific threshold value.
7.1 Replacing a Fan
Required Tools: Plastic tweezers
Stop!
Use only plastic tweezers to avoid short circuiting the power.
7.1.1 Removing the Fan
The replacement of a fan is done from the front, (see Figure 17 - example
from EXN104). Use the wires (with the tweezers) to pull out the plug. Use
the wires to pull the fan out. In the EDN312 use the tweezers to level the
fan on the opposite side of the wires while pulling it out.
7.1.2 Mounting the new Fan
Stop!
Do not press the rotor directly as this may damage the fan
.
Vue de la page 42